Table 2. Firmware Checkpoints (continued)
Checkpoint Description Action/ Possible Failing FRU
E440 Validate NVRAM, initialize partitions
as needed
1. Verify that the system firmware
levels are at the current release
levels, update as necessary.
2. Replace system board
(location: P1) if problem
persists.
See the note on page 78.
E441 Generate /options node NVRAM
configuration variable properties
1. Verify that the system firmware
levels are at the current release
levels, update as necessary.
2. Replace system board
(location: P1) if problem
persists.
See the note on page 78.
E442 Validate NVRAM partitions 1. Verify that the system firmware
levels are at the current release
levels, update as necessary.
2. Replace system board
(location: P1) if problem
persists.
See the note on page 78.
E443 Generate NVRAM configuration
variable dictionary words
Suspect a system firmware
problem if problem persists. Verify
that the system firmware is at
current release level. Update
back-level system firmware if
necessary.
See the note on page 78.
E500 Configure remote I/O subsystem 1. Configure I/O subsystem.
2. The appearance of this code
indicates that the I/O
subsystem configuration has
started or progressed to the
point where the code can be
displayed.
See the note on page 78.
92 Service Guide