Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
406E 020E Scan control routines detected
memory pair A fault
Memory Pair A, Location: P1-M1.1 x2
406E 0211 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.13
406E 0212 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.3
406E 0213 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.14
406E 0214 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.4
406E 021D Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.3 x4
406E 0221 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.11
406E 0222 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.5
406E 0223 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.12
406E 0224 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.6
406E 022D Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.5 x4
406E 0231 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.9
406E 0232 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.7
406E 0233 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.10
406E 0234 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.8
406E 023D Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-M1.7 x4
406E 02FF Scan control routines detected
memory failure on riser card 1 that
cannot be automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
406E 0300 Scan control routines detected
processor card fault
Processor card Location: P1-C1
406E 0301 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-C1-M8
406E 0302 Scan control routines detected
memory DIMM fault
Memory DIMM Location: P1-C1-M1